New CAT Electric Power

ATC Contactor Based Bypass Isolation Automatic Transfer Switch

Rating Range
100 to 3,000A
Transfer Type
Bypass Isolation
Switch Type
Contactor Based

ATC Contactor-Based Automatic Transfer Switch

Rating Range
40-3,000A
Transfer Type
Open / Closed Transition
Switch Type
Contactor Based

ATC Molded Case Circuit Breaker & Molded Case Switch ATS

Rating Range
30-1,000A
Transfer Type
Open transition
Switch Type
Molded Case

ATC Power Breaker & Case Switch Automatic Transfer Switch

Rating Range
200 to 5,000A
Transfer Type
Open Transition
Switch Type
Power Breaker

ATC Power Breaker Bypass Isolation Open/Closed Transition ATS

Rating Range
200-5,000A
Transfer Type
Bypass isolation, Closed transition
Switch Type
Power Breaker

ATC Service Entrance Rated MCCB & Power Breaker Based ATS

Rating Range
30-5,000A
Transfer Type
Open / Closed / Delayed
Switch Type
Molded Case and Power Breaker

ATC-300+ CONTROLLER

Rating Range
120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type
Switch application dependent
Switch Type
Switch application dependent

ATC-900 CONTROLLER

Rating Range
120 to 600V, single phase and three phase @ 50/60 Hz
Transfer Type
Switch application dependent
Switch Type
Switch application dependent

3512C (60 Hz)

Standby Rating
1,500 ekW
Prime Power Rating
1,360 ekW
Emissions/Fuel Strategy
U.S. EPA Certified

3512C (1750 ekW, 60 Hz)

Standby Rating
1,750 ekW
Prime Power Rating
1,600 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2

3516C (60 Hz)

Standby Rating
2,500/2,250/2,000 ekW
Prime Power Rating
2,250/2,045/1,825 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 2

3516E (60 Hz)

Standby Rating
3,000 ekW
Prime Power Rating
2,725 ekW
Emissions/Fuel Strategy
Tier 2

3516E (60 Hz)

Standby Rating
2,750 ekW
Prime Power Rating
2,500 ekW
Emissions/Fuel Strategy
Tier 2, Low NOx

C1.1 (60 Hz)

Standby Rating
8.8 ekW
Prime Power Rating
8 ekW
Emissions/Fuel Strategy
EU Stage IIIA

C1.5 (60 Hz)

Standby Rating
13/17 ekW
Prime Power Rating
12/15.5 ekW
Emissions/Fuel Strategy
EU Stage IIIA

C13 (60 Hz)

Standby Rating
350/400 ekW
Prime Power Rating
320/365 ekW
Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

C13 (60 Hz)

Standby Rating
350/400 ekW
Prime Power Rating
320/350 ekW
Emissions/Fuel Strategy
Low BSFC

C15 (60 Hz)

Standby Rating
350/400/450/500 ekW
Prime Power Rating
320/365/410/455 ekW
Emissions/Fuel Strategy
U.S. EPA Tier 3 Certified

C175-16 (60 Hz)

Standby Rating
3,365(no fan)/3,250/3,100(no fan)/3,000 ekW
Prime Power Rating
3,115(no fan)/3,000/2,825(no fan)/2,725 ekW
Emissions/Fuel Strategy
Low Fuel, Tier 2

C175-20 (60 Hz)

Standby Rating
4,000 (no fan)/3,900/3,620(no fan)/3,500 ekW
Prime Power Rating
3,600 (no fan)/3,500/3,300 (no fan)/3,180 ekW
Emissions/Fuel Strategy
Low Fuel, Tier 2

G3512 with FAST RESPONSE

Gas Standby Rating
750 ekW @ 0.8pf
Fuel Type
Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy
U.S. EPA Certified for Non-Emergency Stationary Genset

CG132B-12

Continuous Rating
600 kW @1.0pf
Fuel Type
Natural Gas, Biogas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
43.3% / 42.4%

CG132B-8

Continuous Rating
400 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
43.1% / 42.1%

CG170-16

Continuous Rating
1,560 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas
Maximum Electrical Efficiency
43.30%

CG170-16 K

Continuous Rating
1,500 ekW
Fuel Type
Natural Gas
Maximum Electrical Efficiency
40.90%

CG170-12

Continuous Rating
1,200 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas
Maximum Electrical Efficiency
43.40%

CG170-12 K

Continuous Rating
1,125 ekW
Fuel Type
Natural Gas
Maximum Electrical Efficiency
40.90%

CG170B-20

Continuous Rating
2,300 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
45.00%

CG170B-12

Continuous Rating
1,380 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
45.00%

CG170B-16

Continuous Rating
1,840 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
44.70%

CG260-12

Continuous Rating
3,333 / 3,000 ekW @1.0pf
Fuel Type
Natural Gas, Coal Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
43.90%

CG260-16

Continuous Rating
4,300 / 4,000 ekW @1.0pf
Fuel Type
Natural Gas, Biogas, Coal Gas, Associated Gas, Synthesis Gas, Hydrogen Blend (to 25%)
Maximum Electrical Efficiency
44.1 / 43.8%

MEC500

Rated Power (AC Input)
500 kW
Voltage Range (AC Input)
400-660 VAC
Frequency Range
50 or 60 Hz

XGC1900 60Hz 250 mg/Nm3

Rating
1,900 ekW (2,375 kVA) Continuous
Frequency
60 Hz
Voltage
480 V

XQ1140 Tier 4 Final

Rating Prime
910 ekW (1,136 kVA)
Frequency
60 Hz
Voltage
120 - 600V

XQ125 Tier 4 Final

Rating Prime
100 ekW (125 kVA)
Frequency
60 Hz
Voltage
120 - 600 V

XQ20 Tier 4 Final

Rating Prime
16 ekW (20 kVA)
Frequency
60 Hz
Voltage
208 - 480 V

XQ2280 Tier 4 Final

Rating Prime
1,825 ekW (2,280 kVA)
Frequency
60 Hz
Voltage
480/277 V

XQ230 Tier 4 Final

Rating Prime
182 ekW (228 kVA)
Frequency
60 Hz
Voltage
120 - 600 V

XQ330 Tier 4 Final

Rating Prime
264 eKW (330 kVA)
Frequency
50/60 Hz
Voltage
120 - 600 V

XQ35 Tier 4 Final

Rating Prime
27 ekW (35 kVA)
Frequency
60 Hz
Voltage
120 - 600 V

XQ425 Tier 4 Final

Rating Prime
340 ekW (425 kVA)
Frequency
50/60 Hz
Voltage
120 - 600 V

XQ570 Tier 4 Final

Rating Prime
455 ekW (568 kVA)
Frequency
60 Hz
Voltage
120 - 600 V

Cat Customizable Switchgear and Controls

Configuration
Application-specific switchgear with control logic designed to meet any customer's sequence of operations. Examples are 3+ Utilities, CHP applications, complex load shed schemes, etc
Modes of Operation
All modes of paralleling generator sets to each other and to other sources (utility, alternative fuels, wind, etc) can be supported. Caterpillar generation and control experts can design and program the most complex power schemes to meet your critical pow
Application
LV and MV ( 208V - 38 kV) 50 / 60 Hz

Cat EGP Switchgear

Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
Modes of Operation
Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
Application
LV and MV (208V - 38 kV)

Cat Switchgear

Configuration
IP4X
Operating Temperature
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths
600 mm for ABB Emax2 E2 1,600 - 2,500A. 750 mm for ABB Emax2 E4 3,200 - 4,000A. 1,200 mm for ABB Emax2 E6 4,000 - 6,300A.

Cat XLM Switchgear

Configuration
Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications
Modes of Operation
Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power
Application
LV and MV ( 208V - 38 kV

EMCP 4.4 Master Control Panel

Configuration
Remote monitoring and control for up to 8 generator sets via high-speed network. Enables paralleling a group of EMCP 4.4 equipped generator sets to a single utility source.
Modes of Operation
Emergency standby, island, utility paralleling
Application
LV and MV (208V - 38 kV)

Engine Paralleling and Integration Control (EPIC)

Configuration
Remote modular paralleling control system (Master Control Panel for the first 2 generator sets and optional tie breaker, separate add-on control panels for up to 8 additional generator sets, utility paralleling control, and distribution control)
Modes of Operation
Emergency Standby with redundant master control, Utility paralleling, peak shaving, and closed transition to/from Generator Power (with optional utility control panel)
Application
LV and MV (208V-27kV)

Why Quinn

Quinn Company is a top choice for purchasing CAT equipment. And here is why:

25 locations in Central, Southern California and AZ

25 locations in Central, Southern California and AZ

Most regional buyers can see, operate, and walk-around a machine within 48 hours of inquiry.

602 factory-trained technicians

602 factory-trained technicians

Quinn does not subcontract repair. Same technicians sell, service, and warranty.

99% of parts filled within 24 hours

99% of parts filled within 24 hours

Quinn stocks CAT genuine at every location and pulls from the CAT distribution network for the rest.

CAT Certified Operator Training, levels 1 to 3

CAT Certified Operator Training, levels 1 to 3

Reduces operator-error damage and lowers insurance loss claims on owned fleets. Available on-site or at Quinn's training facility.

CAT Financial Pre-Qual at Quote Stage

CAT Financial Pre-Qual at Quote Stage

Most buyers leave the quote conversation with a financing tier already attached.

Over 100 Years as a California CAT Dealer

Over 100 Years as a California CAT Dealer

Quinn has been a CAT dealer since 1919. The longest-tenured CAT dealer in the state.

Quinn Cat Is Here to Support You

If the size class is clear, narrow the model grid above with the type filter and request a quote on the unit you want. If the class is not clear, talk to a Quinn sales specialist. Most calls take 20 minutes and cover application, attachments, financing, and delivery in one pass.